Line Down? Emergency Support
// Collect your data Capture
// Capacity & projects Shift Hero Projects Control panels
Book a Meeting →

Mitsubishi Electric MELSEC-F FX2N · Digital Output Module

Mitsubishi FX2N-16EYR-ES/UL

Order number 65580

ECS rates the FX2N-16EYR-ES/UL as phase-out: still orderable, but on its way out. This is the time to plan, not panic.

  1. Active RolloutSold and supported normally
  2. Phase OutRetirement announced, still orderable
  3. CancellationNormal sale ended, spares may remain
  4. Total DiscontinuationNo manufacturer supply or repair

ECS stage: Phase Out.

Is the Mitsubishi Electric FX2N-16EYR-ES/UL being discontinued?

On ECS's lifecycle assessment, the FX2N-16EYR-ES/UL is in phase-out: still orderable for now, but on its way out.

Source: ECS lifecycle assessment, based on ECS's internal lifecycle data in Command Centre. Last checked . Always confirm a specific part's status with the manufacturer before buying or planning a migration.

What Phase Out means for you

The manufacturer is retiring the part, but you can still buy it. Nothing needs ripping out. Four things are worth doing while it is still easy: find every unit you run, make sure you know where each one is, decide whether to hold spares, and price the move.

How ECS defines Phase Out · all four lifecycle stages

Before replacing an output module

Output modules need a load-by-load check rather than a simple channel-count comparison. We would confirm whether each point is switching relays, solenoids or other loads, the current requirements, common arrangements and any interposing devices.

Those details determine whether a proposed replacement behaves electrically like the original and whether PLC logic or wiring must change. A documented output schedule is particularly valuable if the original module fails before a migration is planned.

ECS engineering guidance

FX2N-16EYR-ES/UL part details

Manufacturer
Mitsubishi Electric
Range
MELSEC-F FX2N
Name
FX2N-16EYR-ES/UL Output extension block
Summary
Output extension block, 16 output points can be expanded. Can be connected after the main unit or extension unit. Power is supplied from the main unit or extension unit. End of Order Date: 03/2028 Discontinued 09/2028 Repair support Date : 09/2035

Common questions about the FX2N-16EYR-ES/UL

Is the Mitsubishi Electric FX2N-16EYR-ES/UL being discontinued?

On ECS's lifecycle assessment, the FX2N-16EYR-ES/UL is in phase-out: still orderable for now, but on its way out.

Can I still buy a FX2N-16EYR-ES/UL?

Yes, through normal channels during the phase-out period. It is the cheapest point to buy any spares you want to hold.

An ECS engineer capturing a control panel on a tablet: PLC, drive and power supply identified and synced to Command Centre

Know where every unit is before one fails.

A Capture audit finds every FX2N-16EYR-ES/UL on your site, photographs it where it sits and checks it against manufacturer lifecycle status, so you know your exposure and where your spares are before a failure stops a line.

  • Every device located, photographed and lifecycle-checked
  • Findings report, plus a populated Command Centre
  • No production downtime
See how Capture works

Other MELSEC-F FX2N parts

All Mitsubishi Electric parts · All manufacturers