Line Down? Emergency Support
// Collect your data Capture
// Capacity & projects Shift Hero Projects Control panels
Book a Meeting →

Mitsubishi Electric MELSEC-F FX3 · Interface Modules

Mitsubishi FX3G-485-BD

Order number 221253

Mitsubishi Electric is retiring the FX3G-485-BD. It can still be ordered, so this is the time to plan, not panic.

  1. Active RolloutSold and supported normally
  2. Phase OutRetirement announced, still orderable
  3. CancellationNormal sale ended, spares may remain
  4. Total DiscontinuationNo manufacturer supply or repair

ECS stage: Phase Out. Mitsubishi Electric's published term: End of Life (EMEA).

Is the Mitsubishi Electric FX3G-485-BD being discontinued?

Yes. The FX3G-485-BD is in phase-out (phase-out announced June 2026, last-time-buy January 2027, support until June 2033): still orderable for now, but on its way out. Mitsubishi Electric lists the FX5-485-BD as a possible replacement.

Source: Mitsubishi Electric Europe, end-of-life notice EOL-PLC-260619-2182. Last checked . Always confirm a specific part's status with the manufacturer before buying or planning a migration.

What Phase Out means for you

The manufacturer is retiring the part, but you can still buy it. Nothing needs ripping out. Four things are worth doing while it is still easy: find every unit you run, make sure you know where each one is, decide whether to hold spares, and price the move to the FX5-485-BD.

How ECS defines Phase Out · all four lifecycle stages

Before replacing a communications module

A communications module can stop a much larger part of the machine than its size suggests. We would document the protocol, node or IP addressing, rack configuration, connected devices and every PLC, HMI or SCADA dependency that references it.

If the migration changes network technology, the scope has to include the equipment at the other end of that link as well as the module itself. Capturing the topology now turns a future fault into a controlled network change rather than a discovery exercise.

ECS engineering guidance

FX3G-485-BD part details

Manufacturer
Mitsubishi Electric
Range
MELSEC-F FX3
Name
FX3G/FX3S expansion board, RS-485 communication
Summary
FX3G/FX3S expansion board, RS-485 communication. Mitsubishi Electric Europe has announced its end of life in the EMEA region: last orders by 31 January 2027, service until 19 June 2033. Mitsubishi lists the FX5-485-BD as a possible replacement, not necessarily fully compatible.
Listed replacement
FX5-485-BD

Common questions about the FX3G-485-BD

Is the Mitsubishi Electric FX3G-485-BD being discontinued?

Yes. The FX3G-485-BD is in phase-out (phase-out announced June 2026, last-time-buy January 2027, support until June 2033): still orderable for now, but on its way out. Mitsubishi Electric lists the FX5-485-BD as a possible replacement.

What replaces the FX3G-485-BD?

Mitsubishi Electric lists the FX5-485-BD as a possible replacement, and says replacements are not necessarily 100% compatible. Check wiring, mounting and program conversion against your machine before planning the change.

Can I still buy a FX3G-485-BD?

Yes, through normal channels during the phase-out period. It is the cheapest point to buy any spares you want to hold.

An ECS engineer capturing a control panel on a tablet: PLC, drive and power supply identified and synced to Command Centre

Know where every unit is before one fails.

A Capture audit finds every FX3G-485-BD on your site, photographs it where it sits and checks it against manufacturer lifecycle status, so you know your exposure and where your spares are before a failure stops a line.

  • Every device located, photographed and lifecycle-checked
  • Findings report, plus a populated Command Centre
  • No production downtime
See how Capture works

Other MELSEC-F FX3 parts

All Mitsubishi Electric parts · All manufacturers