Rockwell SLC 500 · Remote IO Header Module
Rockwell 1747-SN
The 1747-SN is no longer supplied by Rockwell. If one fails, finding a replacement quickly is what matters.
- ActiveSold and supported normally
- Phase OutRetirement announced, still orderable
- CancellationNormal sale ended, spares may remain
- Total DiscontinuationNo manufacturer supply or repair
Is the Rockwell 1747-SN discontinued?
Yes. The 1747-SN is discontinued (since March 2024) and no longer supplied by Rockwell. Its successor is the 5069-AENTR.
Source: Rockwell Automation. Last checked . Always confirm a specific part's status with the manufacturer before buying or planning a migration.
What Total Discontinuation means for you
The manufacturer has finished with the part. You may still find one through surplus or refurbished sellers, or in another site's stores, but that is not a supply chain. Knowing where your units are, and where a spare might be, is what shortens the stoppage when one fails.
How ECS defines Total Discontinuation · all four lifecycle stages
Before replacing a communications module
A communications module can stop a much larger part of the machine than its size suggests. We would document the protocol, node or IP addressing, rack configuration, connected devices and every PLC, HMI or SCADA dependency that references it.
If the migration changes network technology, the scope has to include the equipment at the other end of that link as well as the module itself. Capturing the topology now turns a future fault into a controlled network change rather than a discovery exercise.
ECS engineering guidance
1747-SN part details
- Manufacturer
- Rockwell Automation
- Range
- SLC 500
- Name
- SLC Remote I/O Scanner Module
- Summary
- Allen-Bradley SLC 500 remote I/O scanner module for interfacing an SLC system with Remote I/O networks. Rockwell Automation lists the product as discontinued effective 31-03-2024 and identifies 5069-AENTR as an engineering replacement.
- Successor
5069-AENTR
Common questions about the 1747-SN
Is the Rockwell 1747-SN discontinued?
Yes. The 1747-SN is discontinued (since March 2024) and no longer supplied by Rockwell. Its successor is the 5069-AENTR.
What replaced the 1747-SN?
Rockwell lists the 5069-AENTR as the successor. Check compatibility with your machine before planning the change.
Can I still buy a 1747-SN?
Not from Rockwell. Surplus and refurbished sellers may have stock; check provenance and test before fitting. The 5069-AENTR is the supported route.
Know where every unit is before one fails.
A Capture audit finds every 1747-SN on your site, photographs it where it sits and checks it against manufacturer lifecycle status, so you know your exposure and where your spares are before a failure stops a line.
- Every device located, photographed and lifecycle-checked
- Findings report, plus a populated Command Centre
- No production downtime
Related parts
- 1746-NR8 Rockwell SLC 500 · Analogue Input Module Cancellation
- 1746-OB32E Rockwell SLC 500 · Digital Output Module Cancellation
- 1746-NR4 Rockwell SLC 500 · Analogue Input Module Cancellation
- 6ES7153-1AA03-0XB0 Siemens SIMATIC ET 200M · Remote IO Header Module Cancellation
- 6ES7361-3CA01-0AA0 Siemens SIMATIC S7-300 · Remote IO Header Module Cancellation