Rockwell PanelView · HMI Panel

Rockwell 2711P-RP

Normal sale of the 2711P-RP has ended. Spares may still be available, but the clock is running.

  1. ActiveSold and supported normally
  2. Phase OutRetirement announced, still orderable
  3. CancellationNormal sale ended, spares may remain
  4. Total DiscontinuationNo manufacturer supply or repair

ECS stage: Cancellation.

Is the Rockwell 2711P-RP discontinued?

On ECS's lifecycle assessment, the 2711P-RP has been cancelled: no longer sold as a current product, though spares may remain available for a period.

Source: ECS lifecycle assessment, based on ECS's internal lifecycle data in Command Centre. Last checked . Always confirm a specific part's status with the manufacturer before buying or planning a migration.

What Cancellation means for you

You can no longer order it as a normal product, and nothing new should be designed around it. If machines depend on it, you want spare stock you can rely on and a migration plan. Both start with knowing how many you run and whether each has a backup.

How ECS defines Cancellation · all four lifecycle stages

Before replacing an HMI

With an HMI, the editable application is at least as important as the screen itself. We would secure the source project, record the engineering-software version, PLC communications, recipes or retained data, and measure the panel cut-out.

Conversion utilities can speed up a migration, but older drivers, scripts, alarms and fonts do not always transfer cleanly. A spare display only protects production if the correct application can be restored to it.

ECS engineering guidance

2711P-RP part details

Manufacturer
Rockwell Automation
Range
PanelView
Name
PanelView Plus Standard Logic Module, no flash/RAM memory, DC input
Summary
Allen-Bradley PanelView Plus logic module for 700–1500 terminals, without flash or RAM memory, with DC input. Rockwell Automation lists it as discontinued effective 31-12-2012.
Programming software
Factory Talk View ME
Software versions
Held in Command Centre, matched to firmware
Programming cable
Held in Command Centre

Common questions about the 2711P-RP

Is the Rockwell 2711P-RP discontinued?

On ECS's lifecycle assessment, the 2711P-RP has been cancelled: no longer sold as a current product, though spares may remain available for a period.

Can I still buy a 2711P-RP?

Not as a normal new product. Remaining distributor stock or designated spares may still be available. Buy any you need now.

How do I back up a 2711P-RP?

It is programmed with Factory Talk View ME. The exact software version and cable depend on the unit's firmware. ECS records both for every unit it captures, alongside a verified backup.

An ECS engineer capturing a control panel on a tablet: PLC, drive and power supply identified and synced to Command Centre

With a backup, a failed unit is hours. Without one, it is days.

A Capture audit finds every 2711P-RP on your site, takes a backup of each one it can reach, and records the software version and cable needed to restore it. When a discontinued unit fails and a replacement turns up, the program is ready to load.

  • Every device located, photographed and lifecycle-checked
  • Backups taken on the day, with software version and cable recorded
  • Findings report, plus a populated Command Centre
  • No production downtime
See how Capture works