Mitsubishi Electric MELSEC-L · Analogue Output Module
Mitsubishi L60DA4
Order number 238092
ECS rates the L60DA4 as phase-out: still orderable, but on its way out. This is the time to plan, not panic.
- Active RolloutSold and supported normally
- Phase OutRetirement announced, still orderable
- CancellationNormal sale ended, spares may remain
- Total DiscontinuationNo manufacturer supply or repair
Is the Mitsubishi Electric L60DA4 being discontinued?
On ECS's lifecycle assessment, the L60DA4 is in phase-out: still orderable for now, but on its way out.
Source: ECS lifecycle assessment, based on ECS's internal lifecycle data in Command Centre. Last checked . Always confirm a specific part's status with the manufacturer before buying or planning a migration.
What Phase Out means for you
The manufacturer is retiring the part, but you can still buy it. Nothing needs ripping out. Four things are worth doing while it is still easy: find every unit you run, make sure you know where each one is, decide whether to hold spares, and price the move.
Before replacing an analogue module
With analogue I/O, the difficult part of a migration is often hidden in the configuration: signal type, range, scaling, resolution, isolation and any filtering used by the application.
We would capture both the hardware settings and the PLC scaling logic before choosing a replacement. That gives the commissioning engineer known reference values and avoids trying to recreate process calibration from a failed module.
ECS engineering guidance
L60DA4 part details
- Manufacturer
- Mitsubishi Electric
- Range
- MELSEC-L
- Summary
- D/A output module, 4 channels, 0 to 16000 -10 to +10V, 0-12000 0 to 20mA Transition to make-to-order: September 30, 2026 Order acceptance: Until September 30, 2027 Production discontinuation: October 29, 2027
Common questions about the L60DA4
Is the Mitsubishi Electric L60DA4 being discontinued?
On ECS's lifecycle assessment, the L60DA4 is in phase-out: still orderable for now, but on its way out.
Can I still buy a L60DA4?
Yes, through normal channels during the phase-out period. It is the cheapest point to buy any spares you want to hold.
Know where every unit is before one fails.
A Capture audit finds every L60DA4 on your site, photographs it where it sits and checks it against manufacturer lifecycle status, so you know your exposure and where your spares are before a failure stops a line.
- Every device located, photographed and lifecycle-checked
- Findings report, plus a populated Command Centre
- No production downtime
Related parts
- L06CPU-P Mitsubishi MELSEC-L · Modular CPU Phase Out
- LY41PT1P Mitsubishi MELSEC-L · Digital Output Module Phase Out
- L60AD4 Mitsubishi MELSEC-L · Analogue Input Module Phase Out
- QD62E Mitsubishi MELSEC-Q · High Speed / Counter Input Module Phase Out
- GT2712-STBD Mitsubishi GOT2000 GT27 · HMI Panel Phase Out
- FR-D740-0.75K Mitsubishi FREQROL-D700 · AC-VSD (Variable Speed Drive) Phase Out