Proface GP4000E · HMI Panel
Proface GP-4402WW
Normal sale of the GP-4402WW has ended. Spares may still be available, but the clock is running.
- ActiveSold and supported normally
- Phase OutRetirement announced, still orderable
- CancellationNormal sale ended, spares may remain
- Total DiscontinuationNo manufacturer supply or repair
Is the Proface GP-4402WW discontinued?
The GP-4402WW has been cancelled (since December 2024, support until December 2026): no longer sold as a current product, though spares may remain available for a period. Its successor is the ET-6400WA.
Source: Pro-face / Schneider Electric. Last checked . Always confirm a specific part's status with the manufacturer before buying or planning a migration.
What Cancellation means for you
You can no longer order it as a normal product, and nothing new should be designed around it. If machines depend on it, you want spare stock you can rely on and a migration plan. Both start with knowing how many you run and whether each has a backup.
Before replacing an HMI
With an HMI, the editable application is at least as important as the screen itself. We would secure the source project, record the engineering-software version, PLC communications, recipes or retained data, and measure the panel cut-out.
Conversion utilities can speed up a migration, but older drivers, scripts, alarms and fonts do not always transfer cleanly. A spare display only protects production if the correct application can be restored to it.
ECS engineering guidance
GP-4402WW part details
- Manufacturer
- Proface
- Range
- GP4000E
- Name
- GP4000E Series 7-inch WVGA Resistive Touch HMI Panel
- Summary
- 7-inch WVGA TFT color LCD operator interface with 65,536 colors, analog single-touch resistive panel, 24 VDC input, Ethernet, serial communication, and USB interfaces. End of Sale: 31-12-2024; End of Service: 31-12-2026.
- Successor
ET-6400WA- Programming software
- GP-Pro EX
- Software versions
- Held in Command Centre, matched to firmware
- Programming cable
- Held in Command Centre
Common questions about the GP-4402WW
Is the Proface GP-4402WW discontinued?
The GP-4402WW has been cancelled (since December 2024, support until December 2026): no longer sold as a current product, though spares may remain available for a period. Its successor is the ET-6400WA.
What replaced the GP-4402WW?
Proface lists the ET-6400WA as the successor. Check compatibility with your machine before planning the change.
Can I still buy a GP-4402WW?
Not as a normal new product. Remaining distributor stock or designated spares may still be available. Buy any you need now.
How do I back up a GP-4402WW?
It is programmed with GP-Pro EX. The exact software version and cable depend on the unit's firmware. ECS records both for every unit it captures, alongside a verified backup.
With a backup, a failed unit is hours. Without one, it is days.
A Capture audit finds every GP-4402WW on your site, takes a backup of each one it can reach, and records the software version and cable needed to restore it. When a discontinued unit fails and a replacement turns up, the program is ready to load.
- Every device located, photographed and lifecycle-checked
- Backups taken on the day, with software version and cable recorded
- Findings report, plus a populated Command Centre
- No production downtime