Proface GP4000 Series (W model) · HMI Panel
Proface PFXGP4501TADW
Normal sale of the PFXGP4501TADW has ended. Spares may still be available, but the clock is running.
- Active RolloutSold and supported normally
- Phase OutRetirement announced, still orderable
- CancellationNormal sale ended, spares may remain
- Total DiscontinuationNo manufacturer supply or repair
Is the Proface PFXGP4501TADW discontinued?
The PFXGP4501TADW has been cancelled (since June 2025, support until June 2030): no longer sold as a current product, though spares may remain available for a period.
Source: Pro-face by Schneider Electric. Last checked . Always confirm a specific part's status with the manufacturer before buying or planning a migration.
What Cancellation means for you
You can no longer order it as a normal product, and nothing new should be designed around it. If machines depend on it, you want spare stock you can rely on and a migration plan. Both start with knowing how many you run and whether each has a backup.
Before replacing an HMI
With an HMI, the editable application is at least as important as the screen itself. We would secure the source project, record the engineering-software version, PLC communications, recipes or retained data, and measure the panel cut-out.
Conversion utilities can speed up a migration, but older drivers, scripts, alarms and fonts do not always transfer cleanly. A spare display only protects production if the correct application can be restored to it.
ECS engineering guidance
PFXGP4501TADW part details
- Manufacturer
- Proface
- Range
- GP4000 Series (W model)
- Name
- 10.4" Touch Screen Operator Interface
- Summary
- Pro-face GP4000 series 10.4-inch TFT colour touch-screen HMI (GP-4501TW), 24 V DC powered.
- Programming software
- GP-Pro EX
- Software versions
- Held in Command Centre, matched to firmware
Common questions about the PFXGP4501TADW
Is the Proface PFXGP4501TADW discontinued?
The PFXGP4501TADW has been cancelled (since June 2025, support until June 2030): no longer sold as a current product, though spares may remain available for a period.
Can I still buy a PFXGP4501TADW?
Not as a normal new product. Remaining distributor stock or designated spares may still be available. Buy any you need now.
How do I back up a PFXGP4501TADW?
It is programmed with GP-Pro EX. The exact software version and cable depend on the unit's firmware. ECS records both for every unit it captures, alongside a verified backup.
With a backup, a failed unit is hours. Without one, it is days.
A Capture audit finds every PFXGP4501TADW on your site, takes a backup of each one it can reach, and records the software version and cable needed to restore it. When a discontinued unit fails and a replacement turns up, the program is ready to load.
- Every device located, photographed and lifecycle-checked
- Backups taken on the day, with software version and cable recorded
- Findings report, plus a populated Command Centre
- No production downtime
Related parts
- GP-4402WW Proface GP4000E · HMI Panel Cancellation
- PFXSP5B41 Proface SP5000 Series (Open Box) · HMI Panel Cancellation
- PFXGP4502WADW Proface GP4000E Series · HMI Panel Cancellation
- GT2712-STBD Mitsubishi GOT2000 GT27 · HMI Panel Phase Out
- 2711P-RP Rockwell PanelView · HMI Panel Cancellation
- 2711-M3A18L1 Rockwell PanelView · HMI Panel Cancellation